Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1430842

ABSTRACT

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

2.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1422150

ABSTRACT

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

3.
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Article in English | LILACS | ID: biblio-1278571

ABSTRACT

ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Subject(s)
Humans , Zika Virus/genetics , Zika Virus Infection/diagnosis , Brazil , Chikungunya virus/genetics , Dengue/diagnosis , Dengue Virus/genetics , Chikungunya Fever/diagnosis , Laboratories
4.
Braz. j. infect. dis ; 22(5): 418-423, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-974233

ABSTRACT

ABSTRACT The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p= 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Subject(s)
Humans , RNA, Viral/isolation & purification , Hepatitis C/virology , Hepacivirus/isolation & purification , Viral Load/methods , Real-Time Polymerase Chain Reaction/methods , Antiviral Agents/therapeutic use , Polyethylene Glycols/therapeutic use , Time Factors , Viremia , Recombinant Proteins/therapeutic use , Brazil , RNA, Viral/genetics , RNA, Viral/blood , Prospective Studies , Reproducibility of Results , Interferon-alpha/therapeutic use , Hepatitis C/drug therapy , Hepatitis C/blood , Hepacivirus/genetics , Genotyping Techniques , Genotype
SELECTION OF CITATIONS
SEARCH DETAIL